• Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line
  • Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line
  • Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line
  • Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line
  • Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line
  • Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line

Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line

Type: Bare
Conductor Type: Stranded
Application: Overhead
Conductor Material: Aluminum
Sheath Material: Bare
Insulation Material: Bare
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
AAC
Material Shape
Round Wire
Range of Application
Transmission Power Line
Certification
ISO9001, UL, CCC, RoHS
Brand
QIFAN
Color
Silver
Warranty
10 Years
QC
200
Transport Package
Reel and Drum
Specification
1/0 2/0 4/0
Trademark
qifan
Origin
China
HS Code
761490000
Production Capacity
50ton Per Day

Product Description

 
Transmission Use overhead aluminium cable AAC Conductor for Overhead Use
Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line
1.Features : 
a.High tensile strength 
b.Long life 
c.Light in weight 
d.Suitable for high as well as extra high overhead voltage lines




2.Brief Description: 
AAC conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).AAC CONDUCTOR is available in a wide range of steel varying from as low as 6% to as high as 40 %. The higher strengthAAC CONDUCTORS are used for river crossings, overhead ground wires, installations involving extra long spans etc.. Against any given resistance of conductor, AAC CONDUCTORS may be manufactured for having a wide range of tensile strength as per requirement. The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as with lesser supports. Due to the greater diameter of AAC CONDUCTORS a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.

3.Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. AAC CONDUTOR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. AAC CONDUTORS are used extensively for overhead ground wires, river crossings etc. These AAC CONDUTORS are available with us in various types for meeting the exact requirements of the clients. 



4. AAC all aluminum conductors strand.

IEC standard 
Code Number Area Number of Wires Diameter Linear Mass Rated Strength Max.D.C.Resistence at 20ºC
mm2   Wire Cond. kg/km kN Ω/km
10 10 7 1.35 4.05 27.4 1.95 2.8633
16 16 7 1.71 5.12 43.8 3.04 1.7896
25 25 7 2.13 6.4 68.4 4.5 1.1453
40 40 7 2.7 8.09 109.4 6.8 0.7158
63 63 7 3.39 10.2 172.3 10.39 0.4545
100 100 19 2.59 12.9 274.8 17 0.2877
125 125 19 2.89 14.5 343.6 21.25 0.2302
160 160 19 3.27 16.4 439.8 26.4 0.1798
200 200 19 3.66 18.3 549.7 32 0.1439
250 250 19 4.09 20.5 687.1 40 0.1151
315 315 37 3.29 23 867.9 51.97 0.0916
400 400 37 3.71 26 1102 64 0.0721
450 450 37 3.94 27.5 1239.8 72 0.0641
500 500 37 4.15 29 1377.6 80 0.0577
560 560 37 4.39 30.7 1542.9 89.6 0.0515
630 630 61 3.63 32.6 1738.3 100.8 0.0458
710 710 61 3.85 34.6 1959.1 113.6 0.0407
800 800 61 4.09 36.8 2207.4 128 0.0361
900 900 61 4.33 39 2483.3 144 0.0321
1000 1000 61 4.57 41.1 2759.2 160 0.0289
1120 1120 91 3.96 43.5 3093.5 179.2 0.0258
1250 1250 91 4.18 46 3452.6 200 0.0231
1400 1400 91 4.43 48.7 3866.9 224 0.0207
1500 1500 91 4.58 50.4 4143.1 240 0.0193

BS 215
Code name Nominal Number Cross- Overall Weight Calculated Breaking Load Max.D.C. Resistance at 20ºC
  ( mm² ) ( mm ) ( mm² ) ( mm ) ( kg/km ) daN Ω/km
Midge 22 7/2.06 23.33 6.18 64 399 1.227
Aphis 25 3/3.35 26.44 7.22 74 411 1.081
Gnat 25 7/2.21 26.85 6.63 73 459 1.066
Weevil 30 3/3.66 31.56 7.89 86 486 0.9082
Mosquito  35 7/2.59  36.88 7.77 101 603 0.7762
Ladybird 40 7/2.79 42.8 8.37 117 687 0.6689
Ant 50 7/3.10 52.83 9.3 145 828 0.5419
Fly 60 7/3.40 63.55 10.2 174 990 0.4505
Bluebottle 70 7/3.66 73.65 10.98 202 1134 0.3881
Earwig  75 7/3.78  78.55 11.34 215 1194 0.3644
Grasshopper 80 7/3.91 84.05 11.73 230 1278 0.3406
Clegg 90 7/4.17 95.6 12.51 262 1453 0.2994
Wasp 100 7/4.39 106 13.17 290 1600 0.2702
Beetle 100 19/2.67 106.4 13.35 293 1742 0.2704
Bee  125 7/4.90  132 14.7 361 1944 0.2169
Cricket 150 7/5.36 157.9 16.08 432 2385 0.1818
Hornet 150 19/3.25 157.6 16.25 434 2570 0.1825
Caterpilar 175 19/3.53 185.9 17.65 511 2863 0.1547
Chafer 200 19/3.78 213.2 18.9 587 3240 0.1349
Spider  225 19/3.99  237.6 19.95 654 3601 0.1211
Cockroach 250 19/4.22 265.7 21.1 731 4040 0.1083
Butterfly 300 19/4.65 322.7 23.25 888 4875 0.08916
Moth 350 19/5.00 373.1 25 1027 5637 0.07711
Drone 350 37/3.58 372.4 25.06 1027 5745 0.07741
Locust  400 19/5.36  428.7 26.8 1180 6473 0.0671
Centipede 400 37/3.78 415.2 26.46 1145 6310 0.06944
Maybug 450 37/4.09 486.1 28.63 1340 7401 0.05931
Scorpion 500 37/4.27 529.8 29.89 1461 7998 0.05441
Cicada 600 37/4.65 628.3 32.55 1732 9495 0.04588
Tarantula  750 37/5.23  794.9 36.61 2192 12010 0.03627

ASTM B231
Code Name Total Area Stranding and 
wire diameter
mm
Linear Mass
kg/km
Overall 
Diameter
mm
Nominal 
Breaking Load
daN
Max. D.C. 
Resistance 
at 20ºC
≤Ω/k
AWG or 
MCM
mm2
Peachbell 6 13.29 7/1.554 37 4.67 249 2.1692
Rose 4 21.16 7/1.961 58 5.89 396 1.3624
Iris 2 33.61 7/2.474 93 7.42 597 0.8577
Pansy 1 42.39 7/2.776 117 8.33 732 0.6801
Poppy 1/0 53.48 7/3.119 147 9.36 873 0.5390
Aster 2/0 67.42 7/3.503 186 10.51 1100 0.4276
Phlox 3/0 85.03 7/3.932 234 11.80 1347 0.3390
Oxlip 4/0 107.23 7/4.417 296 13.26 1698 0.2688
Valerian 250 126.71 19/2.931 349 14.57 2062 0.2275
Sneezewort 250 126.71 7/4.80 349 14.4 2007 0.2275
Laurel 266.8 135.16 19/3.01 373 15.05 2200 0.2133
Daisy 266.8 135.16 7/4.96 373 14.9 2141 0.2133
Peony 300 152.0 19/3.193 419 15.97 2403 0.1896
Tulip 336.4 170.45 19/3.381 470 16.91 2695 0.1691
Daffodil 350 177.35 19/3.447 489 17.24 2804 0.1625
Canna 397.5 201.42 19/3.673 555 18.36 3184 0.1431
Goldentuft 450 228 19/3.909 629 19.55 3499 0.1264
Syringa 477 241.68 37/2.882 666 20.19 3849 0.1193
Cosmos 477 241.68 19/4.023 666 20.12 3708 0.1193
Hyacinth 500 253.35 37/2.951 698 20.65 4035 0.1138
Zinnia 500 253.35 19/4.12 698 20.6 3888 0.1138
Dahlia 556.5 282 19/4.346 777 21.73 4327 0.1022
Mistletoe 556.5 282 37/3.114 777 21.79 4362 0.1022
Meadowsweet 600 304 37/3.233 838 22.63 4703 0.0948
Orchid 636 322.25 37/3.33 888 23.31 4985 0.0894
Heuchera 650 329.35 37/3.366 908 23.56 5095 0.0875
Flag 700 354.71 61/2.72 978 24.48 5146 0.0813

DIN 48201
Code Number Caculated Area Stranding and wire Diameter  Overall Diameter Linear Mass Calculated Breaking Load Max D.C.Resistance at 20ºC
mm2 mm2 mm mm kg/km daN Ω,km
16 15.89 7/1.70 5.1 44 290 1.8018
25 24.25 7/2.10 6.3 67 425 1.1808
35 34.36 7/2 50 7.5 94 585 0.8332
50 49.48 7/3.00 9 135 810 0.5786
50 48.36 19/1.80 9 133 860 0.595
70 65.82 19/2.10 10.5 181 1150 0.4371
95 93.27 19/2.50 12.5 256 1595 0.3084
120 117 19/2.50 14 322 1910 0.2459
150 147.1 37/2.25 15.2 406 2570 0.196
185 181.6 37/2.50 17.5 501 3105 0.1587
240 242.54 61/2.25 20.2 670 4015 0.1191
300 299.43 61/2.50 22.5 827 4850 0.0965
400 400.14 61/2.89 26 1105 6190 0.07221
500 499.83 61/3.23 29.1 1381 7600 0.05781
625 626.2 91/2.96 32.6 1733 9690 0.04625
500 802.1 91/3.35 36.8 2219 12055 0.03611
1000 999.71 91/3.74 41.1 2766 14845 0.02897



We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
 
Bare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead LineBare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead LineBare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead LineBare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead LineBare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead LineBare All Aluminium Conductor AAC Trillium 3000mcm Size for Overhead Line

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
1900
Year of Establishment
1994-07-11