Bare All Aluminium Conductor AAC Marigold 1113mcm Size for Overhead Line
Product Details
| Customization: | Available |
|---|---|
| Type: | Bare |
| Conductor Type: | Stranded |
Manufacturer/Factory & Trading Company
360° Virtual Tour
Diamond Member Since 2021
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
High Repeat Buyers Choice
Cooperated with Fortune 500
Years of Export Experience
The supplier has import and export rights
More than 50% of buyers repeatedly choose the supplier
This supplier has Cooperated with Fortune 500 companies
The export experience of the supplier is more than 10 years
Sign In to see all verified strength labels (28)
Find Similar Products
Basic Info.
- Model NO.
- AAC
- Application
- Overhead
- Conductor Material
- Aluminum
- Sheath Material
- Bare
- Insulation Material
- Bare
- Material Shape
- Round Wire
- Range of Application
- Transmission Power Line
- Certification
- ISO9001, CCC, RoHS
- Brand
- QIFAN
- Color
- Silver
- Warranty
- 10 Years
- QC
- 200
- Transport Package
- Reel and Drum
- Specification
- 1/0 2/0 4/0
- Trademark
- qifan
- Origin
- China
- HS Code
- 761490000
- Production Capacity
- 50ton Per Day
Product Description
Transmission Use overhead aluminium cable AAC Conductor for Overhead Use
2.Brief Description:
AAC conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).AAC CONDUCTOR is available in a wide range of steel varying from as low as 6% to as high as 40 %. The higher strengthAAC CONDUCTORS are used for river crossings, overhead ground wires, installations involving extra long spans etc.. Against any given resistance of conductor, AAC CONDUCTORS may be manufactured for having a wide range of tensile strength as per requirement. The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as with lesser supports. Due to the greater diameter of AAC CONDUCTORS a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.
3.Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. AAC CONDUTOR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. AAC CONDUTORS are used extensively for overhead ground wires, river crossings etc. These AAC CONDUTORS are available with us in various types for meeting the exact requirements of the clients.
4. AAC all aluminum conductors strand.
IEC standard
BS 215
ASTM B231
DIN 48201
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
1.Features :
a.High tensile strength
b.Long life
c.Light in weight
d.Suitable for high as well as extra high overhead voltage lines
a.High tensile strength
b.Long life
c.Light in weight
d.Suitable for high as well as extra high overhead voltage lines
2.Brief Description:
AAC conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).AAC CONDUCTOR is available in a wide range of steel varying from as low as 6% to as high as 40 %. The higher strengthAAC CONDUCTORS are used for river crossings, overhead ground wires, installations involving extra long spans etc.. Against any given resistance of conductor, AAC CONDUCTORS may be manufactured for having a wide range of tensile strength as per requirement. The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as with lesser supports. Due to the greater diameter of AAC CONDUCTORS a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.
3.Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. AAC CONDUTOR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. AAC CONDUTORS are used extensively for overhead ground wires, river crossings etc. These AAC CONDUTORS are available with us in various types for meeting the exact requirements of the clients.
4. AAC all aluminum conductors strand.
IEC standard
| Code Number | Area | Number of Wires | Diameter | Linear Mass | Rated Strength | Max.D.C.Resistence at 20ºC | |
| mm2 | Wire | Cond. | kg/km | kN | Ω/km | ||
| 10 | 10 | 7 | 1.35 | 4.05 | 27.4 | 1.95 | 2.8633 |
| 16 | 16 | 7 | 1.71 | 5.12 | 43.8 | 3.04 | 1.7896 |
| 25 | 25 | 7 | 2.13 | 6.4 | 68.4 | 4.5 | 1.1453 |
| 40 | 40 | 7 | 2.7 | 8.09 | 109.4 | 6.8 | 0.7158 |
| 63 | 63 | 7 | 3.39 | 10.2 | 172.3 | 10.39 | 0.4545 |
| 100 | 100 | 19 | 2.59 | 12.9 | 274.8 | 17 | 0.2877 |
| 125 | 125 | 19 | 2.89 | 14.5 | 343.6 | 21.25 | 0.2302 |
| 160 | 160 | 19 | 3.27 | 16.4 | 439.8 | 26.4 | 0.1798 |
| 200 | 200 | 19 | 3.66 | 18.3 | 549.7 | 32 | 0.1439 |
| 250 | 250 | 19 | 4.09 | 20.5 | 687.1 | 40 | 0.1151 |
| 315 | 315 | 37 | 3.29 | 23 | 867.9 | 51.97 | 0.0916 |
| 400 | 400 | 37 | 3.71 | 26 | 1102 | 64 | 0.0721 |
| 450 | 450 | 37 | 3.94 | 27.5 | 1239.8 | 72 | 0.0641 |
| 500 | 500 | 37 | 4.15 | 29 | 1377.6 | 80 | 0.0577 |
| 560 | 560 | 37 | 4.39 | 30.7 | 1542.9 | 89.6 | 0.0515 |
| 630 | 630 | 61 | 3.63 | 32.6 | 1738.3 | 100.8 | 0.0458 |
| 710 | 710 | 61 | 3.85 | 34.6 | 1959.1 | 113.6 | 0.0407 |
| 800 | 800 | 61 | 4.09 | 36.8 | 2207.4 | 128 | 0.0361 |
| 900 | 900 | 61 | 4.33 | 39 | 2483.3 | 144 | 0.0321 |
| 1000 | 1000 | 61 | 4.57 | 41.1 | 2759.2 | 160 | 0.0289 |
| 1120 | 1120 | 91 | 3.96 | 43.5 | 3093.5 | 179.2 | 0.0258 |
| 1250 | 1250 | 91 | 4.18 | 46 | 3452.6 | 200 | 0.0231 |
| 1400 | 1400 | 91 | 4.43 | 48.7 | 3866.9 | 224 | 0.0207 |
| 1500 | 1500 | 91 | 4.58 | 50.4 | 4143.1 | 240 | 0.0193 |
BS 215
| Code name | Nominal | Number | Cross- | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
| ( mm² ) | ( mm ) | ( mm² ) | ( mm ) | ( kg/km ) | daN | Ω/km | |
| Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
| Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
| Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
| Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
| Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
| Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
| Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
| Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
| Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
| Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
| Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
| Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
| Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
| Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
| Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
| Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
| Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
| Caterpilar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
| Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
| Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
| Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
| Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
| Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
| Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
| Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
| Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
| Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
| Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
| Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
| Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
ASTM B231
| Code Name | Total Area | Stranding and wire diameter mm |
Linear Mass kg/km |
Overall Diameter mm |
Nominal Breaking Load daN |
Max. D.C. Resistance at 20ºC ≤Ω/k |
|
| AWG or MCM |
mm2 | ||||||
| Peachbell | 6 | 13.29 | 7/1.554 | 37 | 4.67 | 249 | 2.1692 |
| Rose | 4 | 21.16 | 7/1.961 | 58 | 5.89 | 396 | 1.3624 |
| Iris | 2 | 33.61 | 7/2.474 | 93 | 7.42 | 597 | 0.8577 |
| Pansy | 1 | 42.39 | 7/2.776 | 117 | 8.33 | 732 | 0.6801 |
| Poppy | 1/0 | 53.48 | 7/3.119 | 147 | 9.36 | 873 | 0.5390 |
| Aster | 2/0 | 67.42 | 7/3.503 | 186 | 10.51 | 1100 | 0.4276 |
| Phlox | 3/0 | 85.03 | 7/3.932 | 234 | 11.80 | 1347 | 0.3390 |
| Oxlip | 4/0 | 107.23 | 7/4.417 | 296 | 13.26 | 1698 | 0.2688 |
| Valerian | 250 | 126.71 | 19/2.931 | 349 | 14.57 | 2062 | 0.2275 |
| Sneezewort | 250 | 126.71 | 7/4.80 | 349 | 14.4 | 2007 | 0.2275 |
| Laurel | 266.8 | 135.16 | 19/3.01 | 373 | 15.05 | 2200 | 0.2133 |
| Daisy | 266.8 | 135.16 | 7/4.96 | 373 | 14.9 | 2141 | 0.2133 |
| Peony | 300 | 152.0 | 19/3.193 | 419 | 15.97 | 2403 | 0.1896 |
| Tulip | 336.4 | 170.45 | 19/3.381 | 470 | 16.91 | 2695 | 0.1691 |
| Daffodil | 350 | 177.35 | 19/3.447 | 489 | 17.24 | 2804 | 0.1625 |
| Canna | 397.5 | 201.42 | 19/3.673 | 555 | 18.36 | 3184 | 0.1431 |
| Goldentuft | 450 | 228 | 19/3.909 | 629 | 19.55 | 3499 | 0.1264 |
| Syringa | 477 | 241.68 | 37/2.882 | 666 | 20.19 | 3849 | 0.1193 |
| Cosmos | 477 | 241.68 | 19/4.023 | 666 | 20.12 | 3708 | 0.1193 |
| Hyacinth | 500 | 253.35 | 37/2.951 | 698 | 20.65 | 4035 | 0.1138 |
| Zinnia | 500 | 253.35 | 19/4.12 | 698 | 20.6 | 3888 | 0.1138 |
| Dahlia | 556.5 | 282 | 19/4.346 | 777 | 21.73 | 4327 | 0.1022 |
| Mistletoe | 556.5 | 282 | 37/3.114 | 777 | 21.79 | 4362 | 0.1022 |
| Meadowsweet | 600 | 304 | 37/3.233 | 838 | 22.63 | 4703 | 0.0948 |
| Orchid | 636 | 322.25 | 37/3.33 | 888 | 23.31 | 4985 | 0.0894 |
| Heuchera | 650 | 329.35 | 37/3.366 | 908 | 23.56 | 5095 | 0.0875 |
| Flag | 700 | 354.71 | 61/2.72 | 978 | 24.48 | 5146 | 0.0813 |
DIN 48201
| Code Number | Caculated Area | Stranding and wire Diameter | Overall Diameter | Linear Mass | Calculated Breaking Load | Max D.C.Resistance at 20ºC |
| mm2 | mm2 | mm | mm | kg/km | daN | Ω,km |
| 16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 |
| 25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 |
| 35 | 34.36 | 7/2 50 | 7.5 | 94 | 585 | 0.8332 |
| 50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 |
| 50 | 48.36 | 19/1.80 | 9 | 133 | 860 | 0.595 |
| 70 | 65.82 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 |
| 95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3084 |
| 120 | 117 | 19/2.50 | 14 | 322 | 1910 | 0.2459 |
| 150 | 147.1 | 37/2.25 | 15.2 | 406 | 2570 | 0.196 |
| 185 | 181.6 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 |
| 240 | 242.54 | 61/2.25 | 20.2 | 670 | 4015 | 0.1191 |
| 300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 |
| 400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.07221 |
| 500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.05781 |
| 625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 |
| 500 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.03611 |
| 1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.02897 |
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.





Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Conductor
- AAC
- Bare All Aluminium Conductor AAC Marigold 1113mcm Size for Overhead Line
Related Categories
Hot Searches
More