A China top 10 cable manufacturer with 30 years cable production experience.
Cable model
V V 72-0.6/1kV ,V V 32-0.6/1kV
scope of application
This product is suitable for power supply and distribution energy in lines with AC 50Hz and rated voltage not exceeding 0.6 / 1kV.
construction of cable
electric conductor
Class 1 or class 2 of copper conductor
insulation
PVC (PVC)
Filled (optional)
Polypropylene mesh tear cord
Inner sheath PVC
armour
Aluminum wire or stainless steel wire
(single core)
Galvanized steel wire (multi-core)
oversheath
PVC
product standard
GB/T 12706.1,IEC 60502-1
Specifications range
1 core: 10~630mm2
2 cores: 1.5~400mm2
3-core: 1.5~400mm2
4-core: 1.5~400mm2
5-core: 1.5~400mm2
3 + 1 core: 2.5~400mm2
3 + 2 core: 2.5~400mm2
4 + 1 core: 2.5~400mm2
Wire core recognition
2 core: red blue
3 core: yellow green red or red blue yellow / green
4 core: yellow green red blue
5 core: yellow green red blue yellow / green
technical parameter
rated voltage (U0/U )
0.6/1kV
Maximum system voltage (Um)
1.2kV
temperature grade
Maximum operating temperature of the conductor: + 70ºC
Ambient temperature: -20ºC ~ + 45ºC
Cable laying temperature: not less than 0ºC (if the ambient temperature is less than 0ºC, the cable shall be preheated)
minimum bending radius
Single-core cable: 15D
Multi-core cable: 12D
Note: D, which is the actual outer diameter of the cable
Laying method
Pipe-through laying, shallow channel laying, cable trench laying, tunnel laying, interlayer laying, supporting overhead laying, hanging overhead laying, etc.
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation mm | Inner sheath thickness m m |
metal wire nominal diameter mm |
Outer sheath Nominal thickness of mm |
cable Approximately outer diameter mm |
The approximate weight of the cable kg / km | |
Stainless steel wire armor | aluminium wire armour |
|||||||
1×10 | 4.0 | 1.0 | 1.0 | 0.8 | 1.4 | 13.1 | 353 | / |
1×16 | 5.0 | 1.0 | 1.0 | 0.8 | 1.4 | 14.1 | 437 | / |
1×25 | 6.1 | 1.2 | 1.0 | 0.8 | 1.4 | 15.6 | 571 | / |
1×35 | 7.2 | 1.2 | 1.0 | 0.8 | 1.4 | 16.7 | 690 | / |
1×50 | 8.4 | 1.4 | 1.0 | 1.25 | 1.5 | 19.4 | 1003 | 775 |
1×70 | 10.0 | 1.4 | 1.0 | 1.25 | 1.5 | 21.0 | 1256 | 1002 |
1×95 | 12.0 | 1.6 | 1.0 | 1.25 | 1.6 | 23.7 | 1613 | 1320 |
1×120 | 13.0 | 1.6 | 1.0 | 1.6 | 1.7 | 25.6 | 2021 | 1627 |
1×150 | 14.9 | 1.8 | 1.0 | 1.6 | 1.7 | 27.9 | 2409 | 1961 |
1×185 | 16.5 | 2.0 | 1.0 | 1.6 | 1.8 | 30.1 | 2845 | 2365 |
1×240 | 18.4 | 2.2 | 1.0 | 1.6 | 1.9 | 32.6 | 3520 | 2987 |
1×300 | 21.0 | 2.4 | 1.2 | 2.0 | 2.0 | 37.2 | 4542 | 3792 |
1×400 | 23.4 | 2.6 | 1.2 | 2.0 | 2.1 | 40.3 | 5547 | 4714 |
1×500 | 26.6 | 2.8 | 1.2 | 2.0 | 2.2 | 44.1 | 6788 | 5871 |
1×630 | 30.0 | 2.8 | 1.2 | 2.0 | 2.4 | 47.9 | 8293 | 7293 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | Inner sheath thickness mm | Nominal diameter of the armour wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
2×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 14.6 | 341 |
2×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 15.4 | 387 |
2×4 | 2.25 | 1.0 | 1.0 | 0.8 | 1.8 | 17.2 | 483 |
2×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 19.1 | 679 |
2×10 | 4.0 | 1.0 | 1.0 | 1.25 | 1.8 | 21.5 | 859 |
2×16 | 5.0 | 1.0 | 1.0 | 1.25 | 1.8 | 23.5 | 1059 |
2×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.8 | 27.2 | 1535 |
2×35 | 7.2 | 1.2 | 1.0 | 1.6 | 1.8 | 29.4 | 1828 |
2×50 | 8.4 | 1.4 | 1.0 | 1.6 | 1.9 | 33.1 | 2285 |
2×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.0 | 37.9 | 3157 |
2×95 | 12.0 | 1.6 | 1.2 | 2.0 | 2.2 | 43.1 | 4049 |
2×120 | 13.0 | 1.6 | 1.2 | 2.0 | 2.3 | 45.3 | 4654 |
2×150 | 14.9 | 1.8 | 1.4 | 2.5 | 2.4 | 51.6 | 6050 |
2×185 | 16.5 | 2.0 | 1.4 | 2.5 | 2.6 | 56.0 | 7135 |
2×240 | 18.4 | 2.2 | 1.4 | 2.5 | 2.8 | 61.0 | 8662 |
2×300 | 21.0 | 2.4 | 1.6 | 2.5 | 2.9 | 67.7 | 10490 |
2×400 | 23.4 | 2.6 | 1.6 | 2.5 | 3.2 | 73.9 | 12753 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | Inner sheath thickness mm | Nominal diameter of the armoured wire mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable kg / km |
3×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 15.1 | 376 |
3×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 15.9 | 432 |
3×4 | 2.25 | 1.0 | 1.0 | 1.25 | 1.8 | 18.8 | 680 |
3×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 19.8 | 776 |
3×10 | 4.0 | 1.0 | 1.0 | 1.25 | 1.8 | 22.5 | 1009 |
3×16 | 5.0 | 1.0 | 1.0 | 1.25 | 1.8 | 24.6 | 1265 |
3×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.8 | 28.6 | 1855 |
3×35 | 7.2 | 1.2 | 1.0 | 1.6 | 1.8 | 31.2 | 2248 |
3×50 | 8.4 | 1.4 | 1.0 | 1.6 | 2.0 | 35.1 | 2835 |
3×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.1 | 40.2 | 3962 |
3×95 | 12.0 | 1.6 | 1.2 | 2.0 | 2.2 | 45.6 | 5070 |
3×120 | 13.0 | 1.6 | 1.2 | 2.0 | 2.3 | 47.9 | 5923 |
3×150 | 14.9 | 1.8 | 1.4 | 2.5 | 2.5 | 54.7 | 7676 |
3×185 | 16.5 | 2.0 | 1.4 | 2.5 | 2.7 | 59.5 | 9116 |
3×240 | 18.4 | 2.2 | 1.6 | 2.5 | 2.9 | 65.3 | 11289 |
3×300 | 21.0 | 2.4 | 1.6 | 2.5 | 3.1 | 72.2 | 13681 |
3×400 | 23.4 | 2.6 | 1.8 | 3.15 | 3.4 | 80.6 | 17764 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | inside liner thickness mm |
Nominal diameter of the armour wire mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
4×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 15.9 | 422 |
4×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 16.8 | 489 |
4×4 | 2.25 | 1.0 | 1.0 | 1.25 | 1.8 | 19.9 | 767 |
4×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 21.1 | 897 |
4×10 | 4.0 | 1.0 | 1.0 | 1.25 | 1.8 | 24.1 | 1184 |
4×16 | 5.0 | 1.0 | 1.0 | 1.6 | 1.8 | 27.2 | 1663 |
4×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.8 | 31.1 | 2228 |
4×35 | 7.2 | 1.2 | 1.0 | 1.6 | 1.9 | 33.9 | 2738 |
4×50 | 8.4 | 1.4 | 1.2 | 2.0 | 2.1 | 39.6 | 3798 |
4×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.2 | 43.7 | 4846 |
4×95 | 12.0 | 1.6 | 1.4 | 2.5 | 2.4 | 51.4 | 6802 |
4×120 | 13.0 | 1.6 | 1.4 | 2.5 | 2.5 | 54.0 | 7913 |
4×150 | 14.9 | 1.8 | 1.4 | 2.5 | 2.7 | 60.0 | 9487 |
4×185 | 16.5 | 2.0 | 1.6 | 2.5 | 2.9 | 65.7 | 11434 |
4×240 | 18.4 | 2.2 | 1.6 | 2.5 | 3.1 | 71.7 | 14183 |
4×300 | 21.0 | 2.4 | 1.6 | 2.5 | 3.3 | 79.4 | 17208 |
4×400 | 23.4 | 2.6 | 1.8 | 3.15 | 3.6 | 88.5 | 22351 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the outer sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
5×1.5 | 1.38 | 0.8 | 1.0 | 0.8 | 1.8 | 16.7 | 468 |
5×2.5 | 1.78 | 0.8 | 1.0 | 0.8 | 1.8 | 17.8 | 553 |
5×4 | 2.25 | 1.0 | 1.0 | 1.25 | 1.8 | 21.1 | 867 |
5×6 | 2.76 | 1.0 | 1.0 | 1.25 | 1.8 | 22.5 | 1032 |
5×10 | 4.0 | 1.0 | 1.0 | 1.6 | 1.8 | 26.5 | 1518 |
5×16 | 5.0 | 1.0 | 1.0 | 1.6 | 1.8 | 29.2 | 1932 |
5×25 | 6.1 | 1.2 | 1.0 | 1.6 | 1.9 | 33.7 | 2632 |
5×35 | 7.2 | 1.2 | 1.2 | 2.0 | 2.0 | 38.2 | 3559 |
5×50 | 8.4 | 1.4 | 1.2 | 2.0 | 2.2 | 43.0 | 4495 |
5×70 | 10.0 | 1.4 | 1.2 | 2.0 | 2.3 | 47.5 | 5756 |
5×95 | 12.0 | 1.6 | 1.4 | 2.5 | 2.5 | 55.9 | 8080 |
5×120 | 13.0 | 1.6 | 1.4 | 2.5 | 2.7 | 59.0 | 9457 |
5×150 | 14.9 | 1.8 | 1.6 | 2.5 | 2.9 | 66.0 | 11477 |
5×185 | 16.5 | 2.0 | 1.6 | 2.5 | 3.0 | 71.7 | 13732 |
5×240 | 18.4 | 2.2 | 1.8 | 3.15 | 3.3 | 80.3 | 18105 |
5×300 | 21.0 | 2.4 | 1.8 | 3.15 | 3.6 | 89.0 | 22013 |
5×400 | 23.4 | 2.6 | 1.8 | 3.15 | 3.9 | 97.2 | 27030 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
3×2.5+1×1.5 | 1.78/1.38 | 0.8/0.8 | 1.0 | 0.8 | 1.8 | 16.6 | 472 |
3×4+1×2.5 | 2.25/1.78 | 1.0/0.8 | 1.0 | 1.25 | 1.8 | 19.3 | 728 |
3×6+1×4 | 2.76/2.25 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 20.7 | 860 |
3×10+1×6 | 4.0/2.76 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 23.2 | 1097 |
3×16+1×10 | 5.0/4.0 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 26.5 | 1576 |
3×25+1×16 | 6.1/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.8 | 29.8 | 2070 |
3×35+1×16 | 7.2/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.9 | 32.3 | 2471 |
3×50+1×25 | 8.4/6.1 | 1.4/1.2 | 1.2 | 2.0 | 2.0 | 37.8 | 3451 |
3×70+1×35 | 10.0/7.2 | 1.4/1.2 | 1.2 | 2.0 | 2.1 | 41.6 | 4383 |
3×95+1×50 | 12.0/8.4 | 1.6/1.4 | 1.2 | 2.0 | 2.3 | 47.3 | 5659 |
3×120+1×70 | 13.0/10.0 | 1.6/1.4 | 1.4 | 2.5 | 2.5 | 51.8 | 7239 |
3×150+1×70 | 14.9/10.0 | 1.8/1.4 | 1.4 | 2.5 | 2.6 | 56.6 | 8475 |
3×185+1×95 | 16.5/12.0 | 2.0/1.6 | 1.4 | 2.5 | 2.7 | 61.8 | 10205 |
3×240+1×120 | 18.4/13.5 | 2.2/1.6 | 1.6 | 2.5 | 2.9 | 67.6 | 12601 |
3×300+1×150 | 21.0/14.9 | 2.4/1.8 | 1.6 | 2.5 | 3.1 | 74.8 | 15277 |
3×400+1×185 | 23.4/16.5 | 2.6/2.0 | 1.8 | 3.15 | 3.4 | 83.5 | 19791 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath layer thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
3×2.5+2×1.5 | 1.78/1.38 | 0.8/0.8 | 1.0 | 0.8 | 1.8 | 17.4 | 518 |
3×4+2×2.5 | 2.25/1.78 | 1.0/0.8 | 1.0 | 1.25 | 1.8 | 20.3 | 797 |
3×6+2×4 | 2.76/2.25 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 22.0 | 963 |
3×10+2×6 | 4.0/2.76 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 25.3 | 1369 |
3×16+2×10 | 5.0/4.0 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 28.2 | 1768 |
3×25+2×16 | 6.1/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.8 | 32.0 | 2352 |
3×35+2×16 | 7.2/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.9 | 34.2 | 2745 |
3×50+2×25 | 8.4/6.1 | 1.4/1.2 | 1.2 | 2.0 | 2.1 | 40.2 | 3885 |
3×70+2×35 | 10.0/7.2 | 1.4/1.2 | 1.2 | 2.0 | 2.2 | 44.3 | 4921 |
3×95+2×50 | 12.0/8.4 | 1.6/1.4 | 1.4 | 2.5 | 2.4 | 51.9 | 6839 |
3×120+2×70 | 13.0/10.0 | 1.6/1.4 | 1.4 | 2.5 | 2.5 | 55.2 | 8175 |
3×150+2×70 | 14.9/10.0 | 1.8/1.4 | 1.4 | 2.5 | 2.7 | 59.9 | 9395 |
3×185+2×95 | 16.5/12.0 | 2.0/1.6 | 1.6 | 2.5 | 2.8 | 66.2 | 11550 |
3×240+2×120 | 18.4/13.5 | 2.2/1.6 | 1.6 | 2.5 | 3.0 | 72.1 | 14160 |
3×300+2×150 | 21.0/14.9 | 2.4/1.8 | 1.6 | 2.5 | 3.3 | 79.8 | 17214 |
3×400+2×185 | 23.4/16.5 | 2.6/2.0 | 1.8 | 3.15 | 3.6 | 89.0 | 22205 |
specifications mm2 |
Conductor diameter of mm | Nominal thickness of the insulation is mm | The inner sheath layer thickness is mm | Nominal diameter of the wire is mm | Nominal thickness of the sheath is mm | The cable approximate outer diameter of mm | The approximate weight of the cable is kg / km |
4×2.5+1×1.5 | 1.78/1.38 | 0.8/0.8 | 1.0 | 0.8 | 1.8 | 17.6 | 536 |
4×4+1×2.5 | 2.25/1.78 | 1.0/0.8 | 1.0 | 1.25 | 1.8 | 20.7 | 832 |
4×6+1×4 | 2.76/2.25 | 1.0/1.0 | 1.0 | 1.25 | 1.8 | 22.2 | 996 |
4×10+1×6 | 4.0/2.76 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 25.8 | 1433 |
4×16+1×10 | 5.0/4.0 | 1.0/1.0 | 1.0 | 1.6 | 1.8 | 28.6 | 1847 |
4×25+1×16 | 6.1/5.0 | 1.2/1.0 | 1.0 | 1.6 | 1.9 | 32.9 | 2489 |
4×35+1×16 | 7.2/5.0 | 1.2/1.0 | 1.0 | 1.6 | 2.0 | 35.6 | 3001 |
4×50+1×25 | 8.4/6.1 | 1.4/1.2 | 1.2 | 2.0 | 2.1 | 41.5 | 4180 |
4×70+1×35 | 10.0/7.2 | 1.4/1.2 | 1.2 | 2.0 | 2.3 | 45.9 | 5343 |
4×95+1×50 | 12.0/8.4 | 1.6/1.4 | 1.4 | 2.5 | 2.5 | 53.9 | 7484 |
4×120+1×70 | 13.0/10.0 | 1.6/1.4 | 1.4 | 2.5 | 2.6 | 57.0 | 8809 |
4×150+1×70 | 14.9/10.0 | 1.8/1.4 | 1.6 | 2.5 | 2.8 | 63.1 | 10473 |
4×185+1×95 | 16.5/12.0 | 2.0/1.6 | 1.6 | 2.5 | 2.9 | 68.8 | 12628 |
4×240+1×120 | 18.4/13.5 | 2.2/1.6 | 1.6 | 2.5 | 3.2 | 75.3 | 15657 |
4×300+1×150 | 21.0/14.9 | 2.4/1.8 | 1.8 | 3.15 | 3.4 | 85.0 | 20095 |
4×400+1×185 | 23.4/16.5 | 2.6/2.0 | 1.8 | 3.15 | 3.7 | 92.8 | 24603 |