Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable

Product Details
Application: Power Cable
Conductor Material: Copper
Cover Material: PVC
Still deciding? Get samples of US$ 1/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
1900
Year of Establishment
1994-07-11
  • Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
  • Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
  • Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
  • Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
  • Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
  • Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
Find Similar Products
  • Overview
  • Product Description
  • Technical Data sheet
  • Detailed Photos
  • Package
  • company introduction
  • Production
  • Project
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
PVC Sheated Swa
Type
Power Cable
Material Shape
Round Wire
Conductor Type
Stranded
Wire Core Material
Bare Copper Wire
Certification
CE, ISO, RoHS, CCC, VDE
Model
Low Voltage Power Cable
Brand
Qifan
Core
Single Core
Cores
Multi Core
Voltage
600V
Products
Power Cable
Armour
Gsw
Armor
Aluminium Wire
Transport Package
Drum/Roll
Specification
power cable
Trademark
Qifan
Origin
China
HS Code
8544492100
Production Capacity
100000000km

Packaging & Delivery

Package Size
2200.00cm * 300.00cm * 2000.00cm
Package Gross Weight
500.000kg

Product Description




 

The cable sales avanue is USD 3.7 Billion in 2023.
A China top 10 cable manufacturer  with 30 years cable production experience. 

Product Description

Cable model
V V 72-0.6/1kV ,V V 32-0.6/1kV

scope of application
This product is suitable for power supply and distribution energy in lines with AC 50Hz and rated voltage not exceeding 0.6 / 1kV.

construction of cable
electric conductor
Class 1 or class 2 of copper conductor
insulation
PVC (PVC)
Filled (optional)
Polypropylene mesh tear cord
Inner sheath PVC
armour
Aluminum wire or stainless steel wire
(single core)
Galvanized steel wire (multi-core)
oversheath
PVC
product standard
GB/T  12706.1,IEC  60502-1

Specifications range
1 core: 10~630mm2
2 cores: 1.5~400mm2
3-core: 1.5~400mm2
4-core: 1.5~400mm2
5-core: 1.5~400mm2
3 + 1 core: 2.5~400mm2
3 + 2 core: 2.5~400mm2
4 + 1 core: 2.5~400mm2

Wire core recognition
2 core: red   blue
3 core: yellow green red or red blue yellow / green
4 core: yellow green red blue
5 core: yellow green red blue yellow / green

technical parameter
rated voltage (U0/U )
0.6/1kV
Maximum system voltage (Um)
1.2kV

temperature grade
Maximum operating temperature of the conductor: + 70ºC
Ambient temperature: -20ºC ~ + 45ºC
Cable laying temperature: not less than 0ºC (if the ambient temperature is less than 0ºC, the cable shall be preheated)

minimum bending radius
Single-core cable: 15D
Multi-core cable: 12D
Note: D, which is the actual outer diameter of the cable

 Laying method
Pipe-through laying, shallow channel laying, cable trench laying, tunnel laying, interlayer laying, supporting overhead laying, hanging overhead laying, etc.


 

 

Technical Data sheet

 

 
Technical data sheet
V V 72-0.6/1kV Cable structure parameters Table 1
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation  mm Inner sheath thickness
m m
metal wire
nominal diameter mm
Outer sheath
Nominal thickness of mm
cable
Approximately outer diameter mm
The approximate weight of the cable kg / km
Stainless steel wire armor aluminium wire
armour
1×10 4.0 1.0 1.0 0.8 1.4 13.1 353 /
1×16 5.0 1.0 1.0 0.8 1.4 14.1 437 /
1×25 6.1 1.2 1.0 0.8 1.4 15.6 571 /
1×35 7.2 1.2 1.0 0.8 1.4 16.7 690 /
1×50 8.4 1.4 1.0 1.25 1.5 19.4 1003 775
1×70 10.0 1.4 1.0 1.25 1.5 21.0 1256 1002
1×95 12.0 1.6 1.0 1.25 1.6 23.7 1613 1320
1×120 13.0 1.6 1.0 1.6 1.7 25.6 2021 1627
1×150 14.9 1.8 1.0 1.6 1.7 27.9 2409 1961
1×185 16.5 2.0 1.0 1.6 1.8 30.1 2845 2365
1×240 18.4 2.2 1.0 1.6 1.9 32.6 3520 2987
1×300 21.0 2.4 1.2 2.0 2.0 37.2 4542 3792
1×400 23.4 2.6 1.2 2.0 2.1 40.3 5547 4714
1×500 26.6 2.8 1.2 2.0 2.2 44.1 6788 5871
1×630 30.0 2.8 1.2 2.0 2.4 47.9 8293 7293
V V 32-0.6/1kV Cable structure parameters Table 2
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation is mm Inner  sheath thickness mm Nominal diameter of the armour wire is mm Nominal thickness of the sheath is mm The cable approximate outer diameter of mm The approximate weight of the cable is kg / km
2×1.5 1.38 0.8 1.0 0.8 1.8 14.6 341
2×2.5 1.78 0.8 1.0 0.8 1.8 15.4 387
2×4 2.25 1.0 1.0 0.8 1.8 17.2 483
2×6 2.76 1.0 1.0 1.25 1.8 19.1 679
2×10 4.0 1.0 1.0 1.25 1.8 21.5 859
2×16 5.0 1.0 1.0 1.25 1.8 23.5 1059
2×25 6.1 1.2 1.0 1.6 1.8 27.2 1535
2×35 7.2 1.2 1.0 1.6 1.8 29.4 1828
2×50 8.4 1.4 1.0 1.6 1.9 33.1 2285
2×70 10.0 1.4 1.2 2.0 2.0 37.9 3157
2×95 12.0 1.6 1.2 2.0 2.2 43.1 4049
2×120 13.0 1.6 1.2 2.0 2.3 45.3 4654
2×150 14.9 1.8 1.4 2.5 2.4 51.6 6050
2×185 16.5 2.0 1.4 2.5 2.6 56.0 7135
2×240 18.4 2.2 1.4 2.5 2.8 61.0 8662
2×300 21.0 2.4 1.6 2.5 2.9 67.7 10490
2×400 23.4 2.6 1.6 2.5 3.2 73.9 12753
 
V V 32-0.6/1kV Cable structure parameters Table 3
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation is mm Inner sheath thickness mm Nominal diameter of the armoured wire  mm Nominal thickness of the sheath is mm The cable approximate outer diameter of mm The approximate weight of the cable  kg / km
3×1.5 1.38 0.8 1.0 0.8 1.8 15.1 376
3×2.5 1.78 0.8 1.0 0.8 1.8 15.9 432
3×4 2.25 1.0 1.0 1.25 1.8 18.8 680
3×6 2.76 1.0 1.0 1.25 1.8 19.8 776
3×10 4.0 1.0 1.0 1.25 1.8 22.5 1009
3×16 5.0 1.0 1.0 1.25 1.8 24.6 1265
3×25 6.1 1.2 1.0 1.6 1.8 28.6 1855
3×35 7.2 1.2 1.0 1.6 1.8 31.2 2248
3×50 8.4 1.4 1.0 1.6 2.0 35.1 2835
3×70 10.0 1.4 1.2 2.0 2.1 40.2 3962
3×95 12.0 1.6 1.2 2.0 2.2 45.6 5070
3×120 13.0 1.6 1.2 2.0 2.3 47.9 5923
3×150 14.9 1.8 1.4 2.5 2.5 54.7 7676
3×185 16.5 2.0 1.4 2.5 2.7 59.5 9116
3×240 18.4 2.2 1.6 2.5 2.9 65.3 11289
3×300 21.0 2.4 1.6 2.5 3.1 72.2 13681
3×400 23.4 2.6 1.8 3.15 3.4 80.6 17764
V V 32-0.6/1kV Cable structure parameters Table 4
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation is mm inside liner
thickness mm
Nominal diameter of the armour wire mm Nominal thickness of the sheath is mm The cable approximate outer diameter of mm The approximate weight of the cable is kg / km
4×1.5 1.38 0.8 1.0 0.8 1.8 15.9 422
4×2.5 1.78 0.8 1.0 0.8 1.8 16.8 489
4×4 2.25 1.0 1.0 1.25 1.8 19.9 767
4×6 2.76 1.0 1.0 1.25 1.8 21.1 897
4×10 4.0 1.0 1.0 1.25 1.8 24.1 1184
4×16 5.0 1.0 1.0 1.6 1.8 27.2 1663
4×25 6.1 1.2 1.0 1.6 1.8 31.1 2228
4×35 7.2 1.2 1.0 1.6 1.9 33.9 2738
4×50 8.4 1.4 1.2 2.0 2.1 39.6 3798
4×70 10.0 1.4 1.2 2.0 2.2 43.7 4846
4×95 12.0 1.6 1.4 2.5 2.4 51.4 6802
4×120 13.0 1.6 1.4 2.5 2.5 54.0 7913
4×150 14.9 1.8 1.4 2.5 2.7 60.0 9487
4×185 16.5 2.0 1.6 2.5 2.9 65.7 11434
4×240 18.4 2.2 1.6 2.5 3.1 71.7 14183
4×300 21.0 2.4 1.6 2.5 3.3 79.4 17208
4×400 23.4 2.6 1.8 3.15 3.6 88.5 22351
 
V V 32-0.6/1kV Cable structure parameters Table 5
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation is mm The inner sheath thickness is mm Nominal diameter of the wire is mm Nominal thickness of the outer sheath is mm The cable approximate outer diameter of mm The approximate weight of the cable is kg / km
5×1.5 1.38 0.8 1.0 0.8 1.8 16.7 468
5×2.5 1.78 0.8 1.0 0.8 1.8 17.8 553
5×4 2.25 1.0 1.0 1.25 1.8 21.1 867
5×6 2.76 1.0 1.0 1.25 1.8 22.5 1032
5×10 4.0 1.0 1.0 1.6 1.8 26.5 1518
5×16 5.0 1.0 1.0 1.6 1.8 29.2 1932
5×25 6.1 1.2 1.0 1.6 1.9 33.7 2632
5×35 7.2 1.2 1.2 2.0 2.0 38.2 3559
5×50 8.4 1.4 1.2 2.0 2.2 43.0 4495
5×70 10.0 1.4 1.2 2.0 2.3 47.5 5756
5×95 12.0 1.6 1.4 2.5 2.5 55.9 8080
5×120 13.0 1.6 1.4 2.5 2.7 59.0 9457
5×150 14.9 1.8 1.6 2.5 2.9 66.0 11477
5×185 16.5 2.0 1.6 2.5 3.0 71.7 13732
5×240 18.4 2.2 1.8 3.15 3.3 80.3 18105
5×300 21.0 2.4 1.8 3.15 3.6 89.0 22013
5×400 23.4 2.6 1.8 3.15 3.9 97.2 27030
V V 32-0.6/1kV Cable structure parameters Table 6
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation is mm The inner sheath  thickness is mm Nominal diameter of the wire is mm Nominal thickness of the sheath is mm The cable approximate outer diameter of mm The approximate weight of the cable is kg / km
3×2.5+1×1.5 1.78/1.38 0.8/0.8 1.0 0.8 1.8 16.6 472
3×4+1×2.5 2.25/1.78 1.0/0.8 1.0 1.25 1.8 19.3 728
3×6+1×4 2.76/2.25 1.0/1.0 1.0 1.25 1.8 20.7 860
3×10+1×6 4.0/2.76 1.0/1.0 1.0 1.25 1.8 23.2 1097
3×16+1×10 5.0/4.0 1.0/1.0 1.0 1.6 1.8 26.5 1576
3×25+1×16 6.1/5.0 1.2/1.0 1.0 1.6 1.8 29.8 2070
3×35+1×16 7.2/5.0 1.2/1.0 1.0 1.6 1.9 32.3 2471
3×50+1×25 8.4/6.1 1.4/1.2 1.2 2.0 2.0 37.8 3451
3×70+1×35 10.0/7.2 1.4/1.2 1.2 2.0 2.1 41.6 4383
3×95+1×50 12.0/8.4 1.6/1.4 1.2 2.0 2.3 47.3 5659
3×120+1×70 13.0/10.0 1.6/1.4 1.4 2.5 2.5 51.8 7239
3×150+1×70 14.9/10.0 1.8/1.4 1.4 2.5 2.6 56.6 8475
3×185+1×95 16.5/12.0 2.0/1.6 1.4 2.5 2.7 61.8 10205
3×240+1×120 18.4/13.5 2.2/1.6 1.6 2.5 2.9 67.6 12601
3×300+1×150 21.0/14.9 2.4/1.8 1.6 2.5 3.1 74.8 15277
3×400+1×185 23.4/16.5 2.6/2.0 1.8 3.15 3.4 83.5 19791
 

V V 32-0.6/1kV Cable structure parameters Table 7
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation is mm The inner sheath layer thickness is mm Nominal diameter of the wire is mm Nominal thickness of the sheath is mm The cable approximate outer diameter of mm The approximate weight of the cable is kg / km
3×2.5+2×1.5 1.78/1.38 0.8/0.8 1.0 0.8 1.8 17.4 518
3×4+2×2.5 2.25/1.78 1.0/0.8 1.0 1.25 1.8 20.3 797
3×6+2×4 2.76/2.25 1.0/1.0 1.0 1.25 1.8 22.0 963
3×10+2×6 4.0/2.76 1.0/1.0 1.0 1.6 1.8 25.3 1369
3×16+2×10 5.0/4.0 1.0/1.0 1.0 1.6 1.8 28.2 1768
3×25+2×16 6.1/5.0 1.2/1.0 1.0 1.6 1.8 32.0 2352
3×35+2×16 7.2/5.0 1.2/1.0 1.0 1.6 1.9 34.2 2745
3×50+2×25 8.4/6.1 1.4/1.2 1.2 2.0 2.1 40.2 3885
3×70+2×35 10.0/7.2 1.4/1.2 1.2 2.0 2.2 44.3 4921
3×95+2×50 12.0/8.4 1.6/1.4 1.4 2.5 2.4 51.9 6839
3×120+2×70 13.0/10.0 1.6/1.4 1.4 2.5 2.5 55.2 8175
3×150+2×70 14.9/10.0 1.8/1.4 1.4 2.5 2.7 59.9 9395
3×185+2×95 16.5/12.0 2.0/1.6 1.6 2.5 2.8 66.2 11550
3×240+2×120 18.4/13.5 2.2/1.6 1.6 2.5 3.0 72.1 14160
3×300+2×150 21.0/14.9 2.4/1.8 1.6 2.5 3.3 79.8 17214
3×400+2×185 23.4/16.5 2.6/2.0 1.8 3.15 3.6 89.0 22205
V V 32-0.6/1kV Cable structure parameters Table 8
specifications
mm2
Conductor diameter of mm Nominal thickness of the insulation is mm The inner sheath  layer thickness is mm Nominal diameter of the wire is mm Nominal thickness of the sheath is mm The cable approximate outer diameter of mm The approximate weight of the cable is kg / km
4×2.5+1×1.5 1.78/1.38 0.8/0.8 1.0 0.8 1.8 17.6 536
4×4+1×2.5 2.25/1.78 1.0/0.8 1.0 1.25 1.8 20.7 832
4×6+1×4 2.76/2.25 1.0/1.0 1.0 1.25 1.8 22.2 996
4×10+1×6 4.0/2.76 1.0/1.0 1.0 1.6 1.8 25.8 1433
4×16+1×10 5.0/4.0 1.0/1.0 1.0 1.6 1.8 28.6 1847
4×25+1×16 6.1/5.0 1.2/1.0 1.0 1.6 1.9 32.9 2489
4×35+1×16 7.2/5.0 1.2/1.0 1.0 1.6 2.0 35.6 3001
4×50+1×25 8.4/6.1 1.4/1.2 1.2 2.0 2.1 41.5 4180
4×70+1×35 10.0/7.2 1.4/1.2 1.2 2.0 2.3 45.9 5343
4×95+1×50 12.0/8.4 1.6/1.4 1.4 2.5 2.5 53.9 7484
4×120+1×70 13.0/10.0 1.6/1.4 1.4 2.5 2.6 57.0 8809
4×150+1×70 14.9/10.0 1.8/1.4 1.6 2.5 2.8 63.1 10473
4×185+1×95 16.5/12.0 2.0/1.6 1.6 2.5 2.9 68.8 12628
4×240+1×120 18.4/13.5 2.2/1.6 1.6 2.5 3.2 75.3 15657
4×300+1×150 21.0/14.9 2.4/1.8 1.8 3.15 3.4 85.0 20095
4×400+1×185 23.4/16.5 2.6/2.0 1.8 3.15 3.7 92.8 24603




 
Detailed Photos

 

Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
 
Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power CableCopper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
 
Package

 


Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable




 
company introduction

Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
 

Production

 

Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
 
 
Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
 
Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable
 
 
Project

 

Copper Conductor PVC Insulated PVC Sheated Swa Armoured Power Cable

Packaging & Shipping

 

------Our Feature------
 
  1. Imported equipment with experienced technical team
    The company have three plant and has 3048 employees which have 206 engineers. Plant has a series of imported production lines including Niehoff copper drawing lines, Troster Germany and Maillefer Finland 500KV VCV lines, stranding machine from Pourtier France, SKET Germany, Caballe Spain, 220KV and 35KV production line plus SIKORA X - RAY 8000 on-line eccentricity measuring unit from Germany
  2. Complete certification system
    Qifan Cable have gotten ISO 9001, ISO 14001, OHSAS 18001. Plant passed TUV, VDE, UL, CE, SAA, BS etc. certificate.
  3. Perfect Production system
    Qifan Cable products cover LV power cable, MV power cable, HV&EHV power cable, ABC cables, ACSR/AAC/AAAC/ACAR/OPGW ,submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, Lan cable, coaxial cable etc.
  4. Perfect Sales service system
    Qifan Cable can offer the OEM/ODM service, Multiple products, Skilled Export sale engineer team, Reasonable price, Reliable quality, Friendly service. Qifan is always your best choice.







 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier