MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA

Product Details
Application: Construction, Overhead, Underground, Industrial, Power Station
Voltage: Medium Voltage Cable
Current: DC & AC
Still deciding? Get samples of US$ 0/Meter
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
1900
Year of Establishment
1994-07-11
  • MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA
  • MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA
  • MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA
  • MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA
  • MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA
  • MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA
Find Similar Products

Basic Info.

Model NO.
YJV32 YJLV32
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS, TUV
Model
Yjv32 Yjv22
Brand
Qifan
Plant No.
3 Plant with 12 Workshop
Engineer No.
206
Free Sample
Yes
Transport Package
Drum
Specification
25-1600mm2
Trademark
QIFAN
Origin
China
HS Code
8544601200
Production Capacity
500km/Month

Product Description

MV Underground Power Cables Outdoor Energy BS 7835 - 6.35/11kV SWA
 

Armoured 3-core cable with XLPE insualtion. Rated voltage 6.35/11 KV


STANDARDS
National : BS 7835


DESCRIPTION
Electric cable with copper conductors, semiconductive conductor screen, XLPE insulation, semiconductive insulation screen, copper metallic screen for each core, LSF bedding, galvanized steel wires armour (SWA), LSF outer sheath


Application
suitable for installation in energy networks where for safety reasons Low Smoke and Halogen Free cables are specified. The cable is suitable for installation underground, in ducts or in air


Note: the cable is suitable for rated voltage 6/10 KV according to IEC 60502-2

Cable Data

Sizes(mm2) Insulation Thickness(mm) App. Overall Dia.(mm) App. Weight(kg/km)(Cu)
3x35 3.4 51.5 4658
3x50 3.4 54.2 5355
3x70 3.4 58.3 6311
3x95 3.4 62.4 7415
3x120 3.4 65.9 8479
3x150 3.4 69.1 9678
3x185 3.4 73.0 11093
3x240 3.4 80.1 14191
3x300 3.4 85.5 16457
3x400 3.4 93.2 20188
 


Note: The single-core armored cables are used for the D.C. system only. If used for the A.C. system, the magnetic isolation should be applied to the steel armor wires of non-magnetical materials that should be used.

3 Operating characteristics
- Rated power-frepuency voltage U0/U: 6.35/11kV.
- Max.admissible operating temperature of the conductor:90ºC.
- Max. short-circurt temperature of conductor shall not exceed 250ºC. (5s maximum duration)
- The ambient temperature under installation should not below 0ºC.
- The bending radius of a single-core cable should not less than 20 times of the cable diameter. 
The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

 
 
 MV Underground Power Cables Outdoor Energy BS7835 - 6.35/11kV SWA

 