Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
(1)AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
(2)The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines,when replacing the aluminum conductor steel reinforced , the AAAC can save 5-8% of the construction cost.
(3)AAAC referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to replace the conventional ACSR.
Code number | Area | Number of wires | Diameter | Linear mass | Rated strength | D.C resistance | |
mm2 | Wire(mm) | Cond(mm) | kg/km | kN | Ohm/km | ||
16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 29 | 7 | 2.3 | 6.9 | 79.5 | 9.44 | 1.1453 |
40 | 46.5 | 7 | 2.91 | 8.72 | 127.1 | 15.1 | 0.7158 |
63 | 73.2 | 7 | 3.65 | 10.9 | 200.2 | 23.06 | 0.4545 |
100 | 116 | 19 | 2.79 | 14 | 319.3 | 37.76 | 0.2877 |
125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.2 | 0.2302 |
160 | 186 | 19 | 3.53 | 17.6 | 511 | 58.56 | 0.1798 |
200 | 232 | 19 | 3.95 | 19.7 | 638.7 | 73.2 | 0.1439 |
250 | 290 | 19 | 4.41 | 22.1 | 798.4 | 91.5 | 0.1151 |
315 | 366 | 37 | 3.55 | 24.8 | 1008.4 | 115.29 | 0.0916 |
400 | 465 | 37 | 4 | 28 | 1280.5 | 146.4 | 0.0721 |
450 | 523 | 37 | 4.24 | 29.7 | 1440.5 | 164.7 | 0.0641 |
500 | 581 | 37 | 4.47 | 31.3 | 1600.6 | 183 | 0.0577 |
560 | 651 | 61 | 3.69 | 33.2 | 1795.3 | 204.96 | 0.0516 |
Code Name | Area | No.of wires | Diameter | Mass per unit length | Rated strength | DC resistance | |
mm2 | Wire(mm) | Cond(mm) | kg/km | kN | Ω/km | ||
BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.748 |
ACACLA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
HAZEL | 59.9 | 7 | 3.3 | 9.9 | 163.4 | 17.66 | 0.5494 |
PLNE | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
HOLLY | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
WILLOW | 89.7 | 7 | 4.04 | 12.1 | 245 | 26.47 | 0.3665 |
OAK | 118.9 | 7 | 4.65 | 14 | 324.5 | 35.07 | 0.2767 |
MULBERRY | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
ASH | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.183 |
ELM | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
POPLAR | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |