Water Resistant Heavy Duty Multicore Core Cable H07rnf 5X2.5 5X6 5g16 4G4 5X50 H07rnf
|
Still deciding? Get samples of $ !
Order Sample
|
Product Details
| Customization: | Available |
|---|---|
| Application: | Construction, Underground, Industrial |
| Voltage: | Low and Medium Voltage Cable |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Manufacturer/Factory & Trading Company
360° Virtual Tour
Secured Trading Service
Diamond Member Since 2021
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
High Repeat Buyers Choice
Cooperated with Fortune 500
Years of Export Experience
The supplier has import and export rights
More than 50% of buyers repeatedly choose the supplier
This supplier has Cooperated with Fortune 500 companies
The export experience of the supplier is more than 10 years
Sign In to see all verified strength labels (28)
Find Similar Products
Basic Info.
- Model NO.
- h07rnf 5x2.5
- Current
- AC Cable
- Insulation Material
- Rubber
- Sheath Material
- Pcp
- Material Shape
- Round Wire
- Wire Core Material
- Bare Copper Wire
- Certification
- ISO, CCC, RoHS, VDE, Ma
- Model
- H07rn-F
- Brand
- Qifan
- Code
- 8544492900
- Cable Voltage
- 450/750V
- Cable Test
- 3.0/5 Min
- Cable Length
- as Requirement
- Delivery Time
- 3-50 Days
- Type
- 5X16
- Mode
- H07rnf 5X16
- Transport Package
- Drums
- Specification
- 1 core 2 core 3 core 4 core 5 core 6 core
- Trademark
- Qifan
- Origin
- China
- HS Code
- 8544492900
- Production Capacity
- 100000000km
Packaging & Delivery
- Package Size
- 1100.00cm * 300.00cm * 1100.00cm
- Package Gross Weight
- 1000.000kg
Product Description
water resistant heavy duty multicore core cable h07rnf 5x2.5 5x6 5G16 4G4 5X50 h07rnf
GeneraI Specification data
TabIe B.2 (continued)
GeneraI Specification dat
TabIe B.2 (concluded)
Our factory
Package




CABLE MODE
H07RN-F 450/750V
APPLICATION
These cables are designed to provide high flexibility and have the capacity to withstand weather, oil/grease, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audiovisual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
PRODUCTS STANDARD
EN 50525-2-21, EN 60228
Flame Retardant according to IEC/EN 60332-1-2
Water Resistant according to AD7
CHARACTERISTICS
Voltage Rating U/Uo 450/750V
Temperature Rating Operating: -40°C to +60°C Minimum installation and use temperature: -25°C
Maximum temperature of short circuit: +200°C
Minimum Bending Radius Fixed: 4 x overall diameter
CONSTRUCTION
Conductor Class 5 flexible copper conductor
Insulation EPR (Ethylene Propylene Rubber) EI4
Sheath PCP (Polychloroprene) EM2
Core Identification
1 core: Black
2 core: Blue Brown
3 core: Green/Yellow Blue Brown
4 core: Green/Yellow Brown Black Grey
5 core: Green/Yellow Blue Brown Black Grey
6 core and Above : Black with White Number Green/Yellow
Sheath Colour
Black

H07RN-F 450/750V
APPLICATION
These cables are designed to provide high flexibility and have the capacity to withstand weather, oil/grease, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audiovisual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
PRODUCTS STANDARD
EN 50525-2-21, EN 60228
Flame Retardant according to IEC/EN 60332-1-2
Water Resistant according to AD7
CHARACTERISTICS
Voltage Rating U/Uo 450/750V
Temperature Rating Operating: -40°C to +60°C Minimum installation and use temperature: -25°C
Maximum temperature of short circuit: +200°C
Minimum Bending Radius Fixed: 4 x overall diameter
CONSTRUCTION
Conductor Class 5 flexible copper conductor
Insulation EPR (Ethylene Propylene Rubber) EI4
Sheath PCP (Polychloroprene) EM2
Core Identification
1 core: Black
2 core: Blue Brown
3 core: Green/Yellow Blue Brown
4 core: Green/Yellow Brown Black Grey
5 core: Green/Yellow Blue Brown Black Grey
6 core and Above : Black with White Number Green/Yellow
Sheath Colour
Black

GeneraI Specification data
TabIe B.1
| 1 | 2 | 3 | 4 | 5 | |
| nominaI cross-sectionaI area of conductors a mm2 |
Thickness of insuIation specified vaIue mm |
Thickness of sheath specified vaIue mm |
Mean overaII diameter | ||
| Lower Iimit mm |
upper Iimit mm |
||||
| 2 X 0,75 2 X 1 2 X 1,5 2 X 2,5 2 X 4 3 X 0,75 3 X 1 3 X 1,5 3 X 2,5 3 X 4 3 X 6 4 X 0,75 4 X 1 4 X 1,5 4 X 2,5 4 X 4 4 X 6 5 X 0,75 5 X 1 5 X 1,5 5 X 2,5 5 X 4 |
0,6 0,6 0,8 0,9 1,0 0,6 0,6 0,8 0,9 1,0 1,0 0,6 0,6 0,8 0,9 1,0 1,0 0,6 0,6 0,8 0,9 1,0 |
0,8 0,9 1,0 1,1 1,2 0,9 0,9 1,0 1,1 1,2 1,4 0,9 0,9 1,1 1,2 1,3 1,5 1,0 1,0 1,1 1,3 1,4 |
5,7 or 3,7 X 6,0 6,1 7,6 9,0 10,6 6,2 6,5 8,0 9,6 11,3 12,8 6,8 7,1 9,0 10,7 12,7 14,2 7,6 8,0 9,8 11,9 14,6 |
7,4 or 4,7 X 7,4 8,0 9,8 11,6 13,7 8,1 8,5 10,4 12,4 14,5 16,3 8,8 9,3 11,6 13,8 16,2 18,1 9,9 10,3 12,7 15,3 18,6 |
|
| a | Not all cable types are specified in all the sizes given here. see the specific clause of the standard, and also clause 1 of EN 50525-1 . | ||||
GeneraI Specification data
TabIe
TabIe
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| Number & nominaI cross sectionaI area of conductors a mm2 |
Thickness of insuIation specified vaIue mm |
Thickness of sheath specified vaIue |
Mean overaII diameter | |||
| one Iayer mm |
Two Iayers | Lower Iimit mm |
upper Iimit mm |
|||
| Inner Iayer mm |
outer Iayer mm |
|||||
| 1 X 1,5 1 X 2,5 1 X 4 1 X 6 1 X 10 1 X 16 1 X 25 1 X 35 1 X 50 1 X 70 1 X 95 1 X 120 1 X 150 1 X 185 1 X 240 1 X 300 1 X 400 1 X 500 1 X 630 2 X 1 2 X 1,5 2 X 2,5 2 X 4 2 X 6 2 X 10 2 X 16 2 X 25 2 X 35 2 X 50 2 X 70 2 X 95 |
0,8 0,9 1,0 1,0 1,2 1,2 1,4 1,4 1,6 1,6 1,8 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,0 0,8 0,8 0,9 1,0 1,0 1,2 1,2 1,4 1,4 1,6 1,6 1,8 |
1,4 1,4 1,5 1,6 1,8 1,9 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,5 3,6 3,8 4,0 4,1 1,3 1,5 1,7 1,8 2,0 3,1 3,3 3,6 3,8 4,2 4,6 5,0 |
- - - - - - - - - 1,0 1,1 1,2 1,3 1,4 1,4 1,4 1,5 1,6 1,6 - - - - - 1,2 1,3 1,4 1,5 1,7 1,8 2,0 |
- - - - - - - - - 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,4 2,5 - - - - - 1,9 2,0 2,2 2,3 2,5 2,8 3,0 |
5,7 6,3 7,2 7,9 9,5 10,8 12,7 14,3 16,5 18,6 20,8 22,8 25,2 27,6 30,6 33,5 37,4 41,3 45,5 7,7 8,5 10,2 11,8 13,1 17,7 20,2 24,3 27,2 31,6 35,8 40,2 |
7,1 7,9 9,0 9,8 11,9 13,4 15,8 17,9 20,6 23,3 26,0 28,6 31,4 34,4 38,3 41,9 46,8 52 57 10,0 11,0 13,1 15,1 16,8 22,6 25,7 30,7 34,3 39,8 45,1 51 |
GeneraI Specification data
TabIe B.2 (continued)
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| Number & nominaI cross sectionaI area of conductors mm2 |
Thickness of insuIation specified vaIue mm |
Thickness of sheath specified vaIue |
Mean overaII diameter | |||
one Iayer mm |
Two Iayers | Lower Iimit mm |
upper Iimit mm |
|||
| Inner Iayer mm |
outer Iayer mm |
|||||
| 3 x 1 3 x 1,5 3 x 2,5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 3 x 150 3 x 185 3 x 240 3 x 300 4 x 1 4 x 1,5 4 x 2,5 4 x 4 4 x 6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 |
0,8
0,8 0,9 1,0 1,0 1,2 1,2 1,4 1,4 1,6 1,6 1,8 1,8 2,0 2,2 2,4 2,6
0,8
0,8 0,9 1,0 1,0 1,2 1,2 1,4 1,4 1,6 1,6 |
1,4 1,6 1,8 1,9 2,1 3,3 3,5 3,8 4,1 4,5 4,8 5,3 5,6 6,0 6,4 7,1 7,7 1,5 1,7 1,9 2,0 2,3 3,4 3,6 4,1 4,4 4,8 5,2 |
- - - - - 1,3 1,4 1,5 1,6 1,8 1,9 2,1 2,2 2,4 2,5 2,8 3,1 - - - - - 1,4 1,4 1,6 1,7 1,9 2,0 |
- - - - - 2,0 2,1 2,3 2,5 2,7 2,9 3,2 3,4 3,6 3,9 4,3 4,6 - - - - - 2,0 2,2 2,5 2,7 2,9 3,2 |
8,3 9,2 10,9 12,7 14,1 19,1 21,8 26,1 29,3 34,1 38,4 43,3 47,4 52 57 65 72 9,2 10,2 12,1 14,0 15,7 20,9 23,8 28,9 32,5 37,7 42,7 |
10,7 11,9 14,0 16,2 18,0 24,2 27,6 33,0 37,1 42,9 48,3 54 60 66 72 82 90 11,9 13,1 15,5 17,9 20,0 26,5 30,1 36,6 41,1 47,5 54 |
GeneraI Specification dat
TabIe B.2 (concluded)
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | |
| Number & nominaI cross sectionaI area of conductors mm2 |
Thickness of insuIation specified vaIue mm |
Thickness of sheath specified vaIue |
Mean overaII diameter | ||||
one Iayer mm |
Two Iayers | Lower Iimit mm |
upper Iimit mm |
||||
| Inner Iayer mm |
outer Iayer mm |
||||||
| 4 x 95 4 x 120 4 x 150 4 x 185 4 x 240 4 x 300 5 x 1 5 x 1,5 5 x 2,5 5 x 4 5 x 6 5 x 10 5 x 16 5 x 25 5 x 35 5 x 50 5 x 70 5 x 95 5 x 120 5 x 150 5 x 185 5 x 240 5 x 300 |
1,8 1,8 2,0 2,2 2,4 2,6 0,8 0,8 0,9 1,0 1,0 1,2 1,2 1,4 1,4 1,6 1,6 1,8 1,8 2,0 2,2 2,4 2,6 |
5,9 6,0 6,5 7,0 7,7 8,4 1,6 1,8 2,0 2,2 2,5 3,6 3,9 4,4 4,6 5,2 5,7 6,3 6,3 6,8 7,4 8,1 8,8 |
2,3 2,4 2,6 2,8 3,1 3,3 - - - - 1,0 1,4 1,5 1,7 1,8 2,1 2,3 2,5 2,5 2,7 3,0 3,2 3,5 |
3,6 3,6 3,9 4,2 4,6 5,1 - - - - 1,5 2,2 2,4 2,7 2,8 3,1 3,4 3,8 3,8 4,1 4,4 4,9 5,3 |
48,4 53 58 64 72 80 10,2 11,2 13,3 15,6 17,5 22,9 26,4 32,0 35,7 41,8 47,5 54 58 64 71 80 88 |
61 66 73 80 91 101 13,1 14,4 17,0 19,9 22,2 29,1 33,3 40,4 45,1 53 60 67 73 80 89 100 111 |
|
| a | Not all cable types are specified in all the sizes given here . see the specific clause of the standard, and also clause 1 of EN 50525 . | ||||||
Our factory
water resistant heavy duty multicore core cable h07rnf 5x2.5 5x6 5G16 4G4 5X50 h07rnf
Package




Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Rubber Cable
- Water Resistant Heavy Duty Multicore Core Cable H07rnf 5X2.5 5X6 5g16 4G4 5X50 H07rnf
Related Categories
Hot Searches
More