Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Application: | Underground |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. of coresxnominal cross section (mm2)
|
Insulation thickness (mm)
|
Sheath thickness(mm)
|
Outer diameter (mm)
|
Maximum DC resistance of conductor at 20ºC
(Ω/km)
copper
|
2×0.75
|
0.6
|
1.20
|
7.1
|
24.5
|
2×1
|
0.6
|
1.20
|
7.3
|
18.1
|
2×1.5
|
0.7
|
1.20
|
8.3
|
12.1
|
2×2.5
|
0.8
|
1.20
|
9.5
|
7.41
|
2×4
|
0.8
|
1.20
|
10.5
|
4.61
|
2×6
|
0.8
|
1.20
|
11.5
|
3.08
|
3×0.75
|
0.6
|
1.20
|
7.5
|
24.5
|
3×1
|
0.6
|
1.20
|
7.7
|
18.1
|
3×1.5
|
0.7
|
1.20
|
8.7
|
12.1
|
3×2.5
|
0.8
|
1.20
|
10.0
|
7.41
|
3×4
|
0.8
|
1.20
|
11.1
|
4.61
|
3×6
|
0.8
|
1.20
|
12.2
|
3.08
|
4×0.75
|
0.6
|
1.20
|
8.0
|
24.5
|
4×1
|
0.6
|
1.20
|
8.3
|
18.1
|
CU/PVC/PVC (NYM) 300/500 VOLT
CU/PVC/PVC (NYMHY) - 300/500 VOLT
CU/PVC/PVC (NYY) - 0.6/1 kV
CU/PVC/PVC (NYYHY) - 450/750 VOLT
CU/PVC (NYA) - 450/750 VOLT
CU/PVC (NYAF) - 450/750 VOLT
H07V-U/H07V-R/H07V-K PVC Flexible Cable
H05V-U/H05V-K/H05V-R PVC Cable
H03VV-F/H05VV-F PVC/PVC Flexible Cable
Type | Name | Laying Site and Requirements | Long-time Permissible Working Temperature of Conductor(ºC) |
227IEC01/05 BV BLV | Copper Conductor,PVC Insulated Wire | Fixed laid in the circumstance of indoor, conduit etc. | 70 |
Aluminium Conductor,PVC Insulated Wire | |||
227IEC 07 BV-90 | Heat Resistant Copper Conductor,PVC Insulated Wire at 90ºC | Fixed laid in the circumstance of high temperature environment and can be laid indoor, conduit etc. | 90 |
BVR | Copper Conductor,PVC Insulated Flexible Wire | Fixed laid where flexibility is required. | 70 |
227-IEC10 BVV | Copper Conductor PVC Insulated and PVC Sheathed Round Wire | Fixed laid where high mechanical protection and moisture are required. They can be laid in the air or underground. | 70 |
BLVV | Aluminium Conductor PVC Insulated and PVC Sheathed Round Wire | ||
BVVB | Copper Conductor PVC Insulated and PVC Sheathed Flat Wire | ||
BLVVB | Aluminium Conductor PVC Insulated and PVC Sheathed Flat Wire | ||
227IEC 02 RV227 IEC 06 RV | Copper Conductor,PVC Insulated Flexible Connector | Mainly used at middle-light type movable euipments, instrument and meters, household appliances, power and lighting and the places where flexibility is required. | 70 |
227IEC 42 RVB | Copper Conductor,PVC Insulated Flat Flexible Connector | ||
RVS | Copper Conductor,PVC Insulated Flexible Twisting Connector | ||
227IEC52 RVV 227IEC53 RVV | Copper Conductor PVC Insulated and PVC Sheathed Round Flexible Connector(Light and Common Type) |